Platinum Wire Ring Counter Electrode Φ0.5*230mm

Platinum is an inert metal and does not participate in the electrode reaction itself, so it is the first choice for the counter electrode. One of the important parameters of the counter electrode is its surface area. The counter electrode must have a large enough area to support the current conduction generated on the working electrode. Platinum electrodes include platinum sheet electrodes, platinum wire electrodes, and platinum mesh electrodes. The platinum wire electrode has a relatively small area ,which is suitable for use in combination with a disc-shaped working electrode. The platinum wire electrode has a variety of shapes and structures, which can be bent according to the length of the platinum wire to be used with various types of electrochemical cells. The insulating rod material of the platinum wire electrode can be PTFE or PEEK rod. As the working electrode undergoes an oxidation or reduction reaction, a gas evolution reaction or a reverse reaction of the working electrode ...

Glassy Carbon Electrode Straight Type PTCFE Rod

Glassy carbon electrode is one of the most widely used working electrodes, and it is a better inert electrode. Glassy carbon electrode has many advantages such as good conductivity, high hardness, high finish, high hydrogen overpotential, and wide polarization range. Its chemical properties are very stable, and it can be used as an inert electrode for direct anodic dissolution testing, and voltammetric determination of cathodes and variable valence ions. Using glassy carbon electrodes as the substrate, chemically modified electrodes can also be prepared. There are four types of insulating rods for glassy carbon electrode jackets. Glassy carbon electrodes are divided into straight type, L type, T type and detachable type. The straight glassy carbon electrode material faces vertically downwards, and the research material is coated on the glassy carbon material surface for testing. The reference electrode is matched with a curved luggin capillary salt bridge close to the material surface ...

Ag AgCl Reference Electrode Silver Silver Chloride Φ6*140mm Glass Rod

In electrochemistry, in order for a specific reaction to occur, a stable electric potential needs to be applied to the working electrode. The potential of the working electrode should always be accurately controlled. This is why a reference electrode is needed as a potential reference standard. Common reference electrodes include Silver Silver Chloride Ag/AgCl reference electrode, saturated calomel electrode,Hg/HgO reference electrode, Hg/Hg2SO4 reference electrode and Non aqueous Ag+ reference electrode,etc. The silver-silver chloride (Ag/AgCl) electrode is the most commonly used reference electrode. Compared with calomel electrodes that use mercury and its salts, Ag/AgCl electrodes are more environmentally friendly. Its electrode potential also has sufficient stability, reliability and reproducibility. Special attention should be paid to maintenance and storage when using Ag/AgCl reference electrode. Before use rinse it with deionized water. If air bubbles are present around the poro...

Platinum Mesh Electrode Without Diagonal Reinforcement 30*30mm

  Platinum is an inert metal and does not participate in the electrode reaction itself, so it is the first choice for the counter electrode. One of the important parameters of the counter electrode is its surface area. The counter electrode must have a large enough area to support the current conduction generated on the working electrode. Platinum electrodes include platinum sheet electrodes, platinum wire electrodes, and platinum mesh electrodes. The area of the platinum mesh electrode is smaller than platinum sheet electrode, and it is also suitable for use in combination with large-size sheet-shaped working electrode materials. There are two types of platinum mesh electrodes. Through a special customized process, a platinum mesh counter electrode with a PTFE insulated rod can be made into an integrated platinum mesh counter electrode. The platinum mesh can also be clamped by a replaceable electrode clamp as a counter electrode. At the same time, in some spectral photoelectrocata...

H Type Electrochemical Cell Sealed 50ml 60ml

  The H Type Electrochemical Cell has a great influence on the electrochemical measurement, especially in the polarization of the potentiostat. The electrolytic cell constitutes the feedback loop of the operational amplifier in the potentiostat. The change of the parameters of the electrolytic cell has a great influence on the stability of the potentiostat. influences. According to different test requirements, electrolytic cells include conventional electrochemical cells, H-type electrochemical cells, corrosion electrochemical cells, photoelectrocatalytic electrochemical cells, in-situ characterization electrochemical cells, and flow electrochemical cells,etc. The H Type Electrochemical Cell has a great influence on the electrochemical measurement, especially in the polarization of the potentiostat. The electrolytic cell constitutes the feedback loop of the operational amplifier in the potentiostat. The change of the parameters of the electrolytic cell has a great influence on the ...

Photoelectrocatalytic Electrochemical Cell Ordinary Cell 150ml 220ml

  The photoelectrochemical cell is suitable for supporting equipment with horizontal and horizontal illumination of the light source. The three electrodes are on the upper part,and the working electrode should be as close as possible to the side of the light window.A vertical electrode clamp or a horizontal electrode clamp can be used to clamp the material for testing,so that the optical instrument can detect the working electrode from the side quartz light window. The ordinary photoelectrochemical cell is the most basic optical reactor.The upper end is directly inserted into the three electrodes,and the working electrode is placed near the light window. characteristic: 1.The main body of the electrolytic cell is customized with high borosilicate glass.This cell is equipped with JGS2 quartz plate, the size of the quartz plate is φ29*3mm. The spectral application range of JGS2 optical quartz glass is 220-2500nm. 2.The reference electrode can be purchased separately:Ag/AgCl electrode...

H-Type In-Situ Raman Spectroscopy Cell With Double Light Window 30ml

  In-situ Raman spectroscopy electrochemical cell is designed and manufactured for studying the in-situ spectra and morphology changes of electrode materials in electrochemical experiments. The working electrode is placed directly under the see-through window, so that the optical instrument can detect the working electrode from the quartz light window above the cell body. Commonly used instruments include optical microscopes, infrared microscopes, X-ray spectrometers, confocal Raman spectrometers, etc. According to different experimental test requirements, the in-situ Raman spectroscopy electrochemical cell is divided into four types: Single cell body with single light window type Single cell body with double light window type H type double cell body with single side light window type H type double cell body with double side light window type H-type double cell body with double-side light window type is an in-situ Raman characterization cell in which the working electrode and the c...